Jual

compressor maneurop tipe mt80hp4ave
Harganego harga tidak terikat
Pesanan Minimum:1
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T), Tunai
Kemas & Pengirimanpacking palet
Negara AsalPerancis
General Characteristics
Model number ( on compressor nameplate) MT80HP4AVE
Code number for Singlepack* MT80-4VI
Code number for Industrial pack* * MT80-4VM
Drawing number 8502012g
Suction and discharge connections Rotolock
Suction connection 1-3/ 4 " Rotolock
Discharge connection 1-1/ 4 " Rotolock
Suction connection with supplied sleeve 1-1/ 8 " ODF
Discharge connection with supplied sleeve 3/ 4 " ODF
Oil sight glass Threaded
Oil equalisation connection 3/ 8' ' flare SAE
Oil drain connection None
LP gauge port Schrader
IPR valve 30 bar / 8 bar
Cylinders 2
Swept volume 135, 78 cm3/ rev
Displacement @ Nominal speed 23.6 m3/ h @ 2900 rpm - 28.5 m3/ h @ 3500 rpm
Net weight 40 kg
Oil charge 1, 8 litre, Mineral - 160P
Maximum system test pressure Low Side / High side 25 bar( g) / 30 bar( g)
Maximum differential test pressure 30 bar
Maximum number of starts per hour 12
Refrigerant charge limit 5 kg
Approved refrigerants R22, R417A-160PZ
Electrical Characteristics
Nominal voltage 380-400V/ 3/ 50Hz - 460V/ 3/ 60Hz
Voltage range 340-440 V @ 50Hz - 414-506 V @ 60Hz
Winding resistance ( between phases) + / - 7% at 25º C 1.9 #
Maximum Continuous Current ( MCC) 18 A
Locked Rotor Amps ( LRA) 80 A
Motor protection Internal overload protector
Recommended Installation torques
Oil sight glass 50 Nm
Power connections / Earth connection Nm / 2 Nm
Mounting bolts 15 Nm